Sr. NoDescriptionUnitQtyRateAmount (Rs)
1EXCAVATION
Excavation for isolated, stripe/combined & Brick foundations in clay and sandy soil including cost of dressing, leveling and compaction in approved manners and disposal of surplus excavated soil away from site, all excavated area will be proof rolled as directed by the Consultant/Engineer incharge.
BasementC.FT59,972
Ground FloorC.FT225
2BACK FILLING
Back Filling including watering and compaction in layers not exceeding 150mm compacted thickness to dry Compaction Test (ASTM D-1557) upto 95% Modified AASHTO by using the borrowed local sand from the local nearby site, as directed by the Consultant/Engineer incharge
C.FT12,000
3TERMITE PROOFING
Providing and applying of Termite Control by spraying FMC Biflex or Mirage 5% SC by Ali Akbar Group in clear water under all floors, excavation including side walls and bottom of all pits & trenches, for footing and under floors.
aBasementS.ft5,452
bGround FloorS.ft6,222
cFirst FloorS.ft4,986
4PLAIN CEMENT CONCRETE UNDER FOUNDATIONS/FLOOR
Providing and laying P.C.C plain cement concrete (1:4:8) using ordinary Portland cement chenab sand and Dina stone 1.5'' down as blinding layer under foundations/floor & swimming pool including confining, leveling, compacting and curing etc. complete in all respect finished smooth as directed by the Consultant/Engineer incharge.
iBasementC.FT5,452
iiColumn FoundationC.ft125
5Water Stopper
Providing and fixing of water stopper 4mm thick and 229 mm wide poly vinyl chloride ribbed bar by Marflex or approved equivalent installed in the centre of x-section of the concrete structure joint of retaining walls, water tanks and expansion joints complete in all respect as per drawings and as directed by the consultant / Engineer. (9" Decora)
iBasement WallR.ft525
iiO.H.W.TR.ft60
6Reinforced Cement Concrete Work (3000 Psi)
Providing, laying, vibrating, compacting, finishing and curing etc. straight or curved, cast in situ reinforced cement concrete at any floor/height/depth, from ready mix plant, 3000 Psi minimum cylinder compressive strength at 28 days, mix using Ordinary Portland Grey Cement, fine aggregate (100% clean lawrence pur sand ) and sargodah crushed coarse aggregate 3/4'' down graded with approved quality admixture by Sika/Imporient or approved equivalent, including laying through pump, vibrating through electro mechanical vibrators, placing of all pipes and embedded items before concreting curing finishing complete but excluding the cost of steel reinforcement complete in all respect as per drawings and as directed by the Consultant/Engineer incharge
6.1Basement Retaining WallsC.ft4,050
6.2Basement Pool WallsC.ft1,335
6.3Basement Pool BaseC.ft473
6.4Basement water body walls & BaseC.ft230
6.5Basement Column FoundationsC.ft1,664
6.6Basement Basement CoulumnC.ft340
6.7Basement LintelC.ft495
6.8Basement Slab & BeamC.ft4,224
6.9Ground Floor Column FoundationsC.ft36
6.10Ground Floor CoulumnC.ft425
6.11Ground Floor LintelC.ft375
6.12Ground Floor Slab & BeamC.ft4,800
6.13First Floor CoulumnC.ft375
6.14First Floor LintelC.ft165
6.15First Floor Slab & BeamC.ft3,314
6.16Baement to first Floor StairC.ft400
6.17O.H.W.T Base and wallsC.ft583
6.18U.G.W.T Base and wallsC.ft252
6.19Septic TankC.ft185
7STEEL REINFORCEMENT
Providing fabricating, laying, fixing, Mild Steel deformed bars (non-TMT) grade 60 with minimum yield stress conforming to ASTM specifications A-615. including cost of cutting, bending, placing, binded annealed binding wire 16 guage, removal of rest from bars if any, in specified overlaps, chairs, sports, spacers, wastage, etc. Complete in all respects by an approved source such as Afco steel, Prime steel, Ittefaq steel, Model Steel, City Steel UAE ( if not available, client will specify the alternate brand. Only the lengths shown on Drawings shall be paid for in accordance with the Bar bending schedule prepared the contractors from the drawings and submitted well in advance to the Engineer for the approval, steel lengths from the site multiply by the standard weights will used for the purpose of payment and duly approved by the consultant/Engineer Incharge.
Ton75
8Brick Work
8.1Providing and laying first class burnt brick work 9"and above thickness to in cement sand mortar (1:5) including all scaffolding, racking out joints and making all flush or groove joints steel dowels at joints to masonry or columns, complete in all respects as per drawing, specifications, and or as directed by the Engineer
8.1Basement 9" Thick WallC.ft414
8.2Basement 13.50" Thick WallC.ft1,384
8.3Ground Floor 15" Thick WallC.ft900
8.4Ground Floor 13.50" Thick WallC.ft1,814
8.5Ground Floor 9" Thick WallC.ft1,206
8.6First Floor 15" Thick WallC.ft825
8.7First Floor 13.50" Thick WallC.ft354
8.8First Floor 9" Thick WallC.ft2,175
8.2Providing and laying first class burnt brick work 4½" thickness to in cement sand mortar (1:4) including all scaffolding, racking out joints and making all flush or groove joints steel dowels at joints to masonry or columns, complete in all respects as per drawing, specifications, and or as directed by the Engineer.
8.2.1Basement FloorS.ft3,264
8.2.2Ground FloorS.ft960
8.2.3First FloorS.ft528
8.2.4Boundary WallS.ft3,960
9Plaster Work
Supply, mix, apply and cure Cement sand plaster of any height, includes making sharp corners, edges, grooves, all scaffolding. complete in all respects as per drawing, specifications, and or as directed by the Engineer
Internal & External PlasterS.ft27,890
10Brick Blast
10.1Basement FloorC.ft1,799
10.2Ground FloorC.ft2,053
10.3First FloorC.ft1,645
11PCC SUB FLOOR
Cement Concrete (1:2:4), including placing, compacting, finishing and curing complete. (Screed Under Floor)
11.1Baement FloorC.ft1,799
11.2Ground FloorC.ft2,053
11.3First FloorC.ft1,645
12Roof insulation and water proofing
Providing and laying Roof insulation and water proofing to roof consisting of given below of as directed by the Engineer incharge. - Bituminous primer coat. - 2-coats of cold applied rubberized bitumen - One layer of polythene 500 gauge - 1½” thick "extruded polystyrene board" 1½" thick. (density 34 Kg/m³) - One layer of polythene 500 gauge - 4” thick average mud (compacted thickness). - Brick tiles 9”x4-1/2”x1-1/2” laid in cement sand mortar 1:4 and grouted with cement sand mortar 1:3 using 1-part of OPC and 3-parts of clean approved quality sand, complete as per drawings, specifications and instructions of the Consultant.
S.ft6,561
13D.P.C
Supply, mix, place, cure, compact concrete (1:2:4) 1-1/2" horizontal damp proof course on brick masonry wall includes form work & mixing of rhombic 707 manufactured by MBT in concrete & application of one coat of same chemical on masonry surface before pouring of mixed concrete according to drawings and manufacturers instructions or As directed by the consultant.
iGround FloorS.ft654
TOTAL AMOUNT RS

Y-101 ( Com) , Phase-3, DHA Lahore Cantt

0321-6995378, +92 42 35692789